Restoration of autophagy-lysosomal function via transcranial focused ultrasound stimulation ameliorates β-amyloid pathology and cognitive deficits in an Alzheimer’s disease model

Mengke Wang, Baochen Zhang, Renhao Guo, Haiqin Wang, Di Wu, Xiaoqian Peng, Hongsong Guo, Jiawei Duan, Weina Yang, Pengyu Ren, Siyuan Zhang

Ultrasonics 2026 · 10.1016/j.ultras.2026.108075

rodentalzheimers diseasebehaviourhistology molecularother

Abstract

Transcranial focused ultrasound (FUS) is a non-invasive neuromodulation technique that regulates intracellular functions and treats brain disorders. In Alzheimer's disease (AD), impaired autophagy-lysosomal pathway (ALP) function leads to the accumulation of β-amyloid (Aβ). However, the potential of FUS alone to alleviate AD pathology by restoring ALP function remains unexplored. In this study, sixteen male transgenic mice with five familial Alzheimer's disease mutations (5×FAD) received bilateral FUS targeting the hippocampus and were compared with sixteen age-matched untreated male 5×FAD mice. Cognitive function was evaluated using behavioral tests, and Aβ pathology was analyzed by immunofluorescence. RNA sequencing, western blotting, and electron microscopy were employed to assess the effects of FUS on the ALP. The results indicated that FUS reduced Aβ deposition and ameliorated cognitive deficits. Compared with the AD group, FUS treatment significantly reduced escape latency by 40.9% (p = 0.010), increased the novel object recognition index by 38.2% (p = 0.016), and increased spontaneous alternation by 18.2% (p = 0.009). Critically, FUS enhanced lysosomal biogenesis and improved autophagosome-lysosome fusion, increasing colocalization efficiency from 28.07 ± 3.73% to 53.22 ± 4.85% in the cortex (p = 0.009) and from 31.95 ± 3.65% to 48.00 ± 2.18% in the hippocampus (p = 0.026). It also promoted the nuclear translocation of transcription factor EB (TFEB). Moreover, the ALP antagonist chloroquine (CQ) suppressed the beneficial effects of FUS, indicating that FUS exerts therapeutic effects in an ALP-dependent manner. Our findings demonstrate that restoring ALP via FUS is a crucial mechanism for mitigating Aβ pathology.

Abstract via europepmc.

Speciesmouse (5xFAD transgenic)
Subjects16, 11swept animals
Sessions per subjectnot reported
Randomisednot reported
Blindingnot reported
Sham / controlundescribed, no treatment control
Auditory controlnot reported
Readout timingoffline
Anaesthesiaanaesthetised
Readoutsbehaviour, histology molecular, other — Morris water maze; novel object recognition; Y-maze; Abeta immunofluorescence; RNA sequencing; western blotting; electron microscopy; H&E
Direction of effectnot assessedNo neural activity readout; FUS reduced Abeta deposition, improved cognition and enhanced autophagosome-lysosome fusion in 5xFAD mice; chloroquine blocked these benefits.
Adverse eventsnone observedH&E staining showed no morphological abnormality or haemorrhage in FUS-treated 5xFAD brains.

Exposures

Exposure 1: Bilateral hippocampal FUS in 5xFAD mice

Target: hippocampus — “bilateral FUS targeting the hippocampus”
Device: not reported

Pulse timing
Waveformpulsed
Fundamental frequency (kHz)1,060✓✓✓
Pulse duration (ms)2✓✓✓
Pulse repetition frequency (Hz)250✓✓✓⚑
Duty cycle (%)not reportedpulse duration × PRF gives 50%⚑
Sonication duration (s)0.2✓✓✓⚑
Pressure and intensity, by domain
Free-field pressure (kPa)not reported
Free-field Isppa (W/cm²)not reported
Free-field Ispta (W/cm²)not reported
In-situ estimatenot reportedsingle value
In-situ pressure (kPa)320✓✓✓
In-situ Isppa (W/cm²)not reported
In-situ Ispta (W/cm²)not reported
Isppa, domain unspecified (W/cm²)3.32✓✓✓⚑
Ispta, domain unspecified (W/cm²)0.064✓✓✓
Protocol, in the paper’s words

Pulse interval 5 s, sonication duration 200 ms, pulse repetition period 4 ms, pulse duration 2 ms; bilateral stimulation 10 min/day each side for 1 month under 2% isoflurane.

Flags from extraction

  • n_subjects — Group sizes given: AD+FUS n=16 and AD+FUS+CQ n=11 (both exposed); abstract also says sixteen FUS mice. Total exposed not stated, so group sizes listed; figure legends show n=4 to 7 per analysis.
  • exposures[0].timing.pulse_repetition_frequency_hz — Paper gives a pulse repetition period of 4 ms, recorded as 250 Hz (unit conversion).
  • exposures[0].timing.duty_cycle_pct — Duty cycle not stated.
  • exposures[0].timing.sonication_duration_s — 200 ms is the sonication duration within a 5 s pulse interval; 10 min per side per day for one month.
  • exposures[0].in_situ.method — 0.32 MPa called 'intracranial' with 18% transcranial attenuation mentioned, but the paper does not say it was derated, simulated or measured.
  • exposures[0].unspecified_domain.isppa_w_cm2 — Isppa and Ispta given with no domain stated.
  • exposures[0].target.terms — Bilateral hippocampus by atlas alignment; the elliptical focal region may also include adjacent tissue.