← Explore

Rapid modulation of choice behavior by ultrasound on the human frontal eye fields

S. Farboud, B. R. Kop, R. S. Koolschijn, S. L. Y. Walstra, J. P. Marques, A. Chetverikov, W. P. Medendorp, L. Verhagen, H. E. M. den Ouden

Nature Communications 2026 · 10.1038/s41467-026-69854-7

human healthyhealthybehaviourother mri

Abstract

A fundamental challenge in neuroscience is establishing causal brain-function relationships with spatial and temporal precision. Transcranial ultrasonic stimulation offers a unique opportunity to modulate deep brain structures non-invasively with high spatial resolution, but temporally precise effects and their neurophysiological foundations have yet to be demonstrated in humans. Here, we develop a temporally precise ultrasound stimulation protocol targeting the frontal eye fields - a well-characterized circuit critical for saccadic eye movements. We demonstrate that ultrasonic stimulation induces robust excitatory behavioral effects. Importantly, individual differences in baseline GABAergic inhibitory tone predict response magnitude. These findings establish ultrasound stimulation as a reliable tool for chronometric circuit interrogation and highlight the importance of neurophysiological state in neuromodulation. This work bridges human and animal research, advancing targeted transcranial ultrasonic stimulation applications in neuroscience and clinical settings.

Abstract via europepmc.

Specieshuman
Subjects39 participants
Sessions per subject2
Randomisedyes
Blindingdouble
Sham / controlsound only, active control site
Auditory controlmasking sound, ramped pulses, post hoc check
Readout timingonline
Anaesthesianot applicable
Readoutsbehaviour, other mri — saccade choice task with eye tracking; baseline GABA+ MRS (MEGA-PRESS)
Direction of effectexcitatoryFEF TUS increased selection of contralateral saccades on short-SOA trials; M1 TUS had no significant effect; effect size related to baseline FEF GABA+.
Adverse eventsnot reportedTemperature rise below 2 C and derated intracranial MI below 1.9 (simulation); participants were queried about symptoms at session end but this was used only for debriefing and not analysed.

Exposures

Exposure 1: FEF (left and right)

Target: frontal eye field — “left or right frontal eye fields (FEF)”
Device: NeuroFUS · Sonic Concepts (sold by Brainbox) · Neuro-FUS PRO system with CTX250-009 and CTX250-014 transducers ✓

Pulse timing
Waveformpulsed
Fundamental frequency (kHz)250✓✓✓
Pulse duration (ms)2✓✓✓
Pulse repetition frequency (Hz)500✓✓✓
Duty cycle (%)not reportedpulse duration × PRF gives 100%⚑
Sonication duration (s)0.5✓✓✓
Pressure and intensity, by domain
Free-field pressure (kPa)900✓✓✓
Free-field Isppa (W/cm²)25✓✓✓⚑
Free-field Ispta (W/cm²)9.37✓✓✓
In-situ estimatesimulation
In-situ pressure (kPa)not reported⚑
In-situ Isppa (W/cm²)not reported
In-situ Ispta (W/cm²)not reported
Protocol, in the paper’s words

TUS delivered for 500 ms per trial starting at onset of the first saccade target; pulse duration 2 ms with 1 ms ramp, PRF 500 Hz, pulse train duration 500 ms; sham trials consisted of the auditory mask only; left/right FEF and left/right M1 blocks counterbalanced over two TUS sessions.

Exposure 2: M1 hand area active control (left and right)

Target: primary motor cortex — “left or right hand motor cortex (M1)”
Device: NeuroFUS · Sonic Concepts (sold by Brainbox) · Neuro-FUS PRO system with CTX250-009 and CTX250-014 transducers ✓

Pulse timing
Waveformpulsed
Fundamental frequency (kHz)250✓✓✓
Pulse duration (ms)2✓✓✓
Pulse repetition frequency (Hz)500✓✓✓
Duty cycle (%)not reportedpulse duration × PRF gives 100%
Sonication duration (s)0.5✓✓✓
Pressure and intensity, by domain
Free-field pressure (kPa)900✓✓✓
Free-field Isppa (W/cm²)25✓✓✓
Free-field Ispta (W/cm²)9.37✓✓✓
In-situ estimatesimulation
In-situ pressure (kPa)not reported
In-situ Isppa (W/cm²)not reported
In-situ Ispta (W/cm²)not reported
Protocol, in the paper’s words

TUS delivered for 500 ms per trial starting at onset of the first saccade target; pulse duration 2 ms with 1 ms ramp, PRF 500 Hz, pulse train duration 500 ms; sham trials consisted of the auditory mask only; left/right FEF and left/right M1 blocks counterbalanced over two TUS sessions.

Flags from extraction

  • exposures[0].timing.duty_cycle_pct — Duty cycle not stated. A 2 ms pulse at 500 Hz PRF (2 ms period) would be 100 %, which does not fit a ramped pulsed protocol; pulse duration and PRF recorded as written, duty cycle left not_reported.
  • exposures[0].free_field.isppa_w_cm2 — Paper gives square-wave equivalent Isppa 25 W/cm2 and an effective Isppa of 9.37 W/cm2 (ramped pulses); the 25 W/cm2 is recorded, effective value is in the quote.
  • n_subjects — 39 enrolled; 3 excluded for eye-tracking failure and replaced, 1 further accuracy outlier; 35 analysed. Enrolled recorded.
  • exposures[0].in_situ.pressure_kpa — Post hoc acoustic simulations were run (Fig. 2B) but no in-situ pressure or intensity value is stated in the text; only derated MI < 1.9 and delta T < 2 C.
  • sham_type — Sham trials were auditory mask only; paper does not state whether the transducer was in place and silent, so recorded as sound_only plus the active M1 control site.