← Explore

Noninvasive Focused Ultrasound as a Safe Modulator of Calcium-Dependent Neurochemical Signalling in Primary Cortical Cultures

Iqra Bano, Pascal Jorratt, Viera Kútna, Jan Pala, Grygoriy Tsenov

Neurochemical Research 2026 · 10.1007/s11064-026-04676-z

in vitro cellhealthycellular imagingother

Abstract

Focused ultrasound stimulation (FUS) is a promising non-invasive neuromodulation technique that can influence neuronal activity through mechanical stimulation. In this study, primary cortical neurons were isolated from embryonic rat brains and cultured for 14 days in vitro before being divided into Control, FUS 5 V, and FUS 10 V groups. Cells were exposed to low-intensity pulsed FUS (300 kHz, 10 min) using a vertically mounted transducer positioned 5 mm above the culture dish. Post-exposure analyses included cell viability using the MTS assay, total protein quantification by the Bradford method, morphological assessment by Trypan Blue staining, and Fluo-3 AM-based confocal calcium imaging. FUS treatment produced no significant differences in viability or total protein concentration compared with the Control group. Morphological observations confirmed healthy neuronal somata and intact neuritic networks across all groups, with no evidence of cell death or structural damage compared with controls. In contrast, calcium imaging revealed a robust transient elevation in intracellular Ca²⁺ responsiveness when assessed 24 h after FUS exposure, with a significantly higher integrated area under the curve relative to Control. These findings demonstrate that low-intensity FUS safely enhances intracellular calcium signalling while preserving neuronal viability, protein integrity, and morphology, defining a safe acoustic window for non-destructive neuromodulation and providing a framework for mechanistic studies in neurodegenerative disease models.

Abstract via europepmc.

Speciesrat (Wistar)
Subjects3 cultures
Sessions per subjectnot applicable
Randomisednot applicable
Blindingnot applicable
Sham / controlinactive transducer
Auditory controlnot reported
Readout timingoffline
Anaesthesianot applicable
Readoutscellular imaging, other — MTS viability assay; Bradford total protein; Trypan Blue morphology; Fluo-3 AM calcium imaging with KCl challenge
Direction of effectexcitatoryCalcium responsiveness (AUC of F/F0 with KCl challenge) was higher 24 h after 10 V FUS than control; viability, protein and morphology were unchanged. Calcium imaging was done at 10 V only.
Adverse eventsnot applicableViability (MTS), total protein and Trypan Blue morphology showed no significant damage at 5 V or 10 V.

Exposures

Exposure 1: FUS 5 V and 10 V drive, 10 min

Target: cultured neurons — “primary cortical neurons (DIV14)”
Device: custom-built · custom immersion-type 300 kHz transducer driven by A-M Systems model 4100 isolated High-Power stimulator

Pulse timing
Waveformpulsed
Fundamental frequency (kHz)300✓✓✓
Pulse duration (ms)500✓✓✓⚑
Pulse repetition frequency (Hz)0.05✓✓✓⚑
Duty cycle (%)not reportedpulse duration × PRF gives 2.5%⚑
Sonication duration (s)600✓✓✓
Pressure and intensity, by domain
Free-field pressure (kPa)not reported⚑
Free-field Isppa (W/cm²)not reported
Free-field Ispta (W/cm²)not reported
In-situ estimatenot applicable
In-situ pressure (kPa)not applicable
In-situ Isppa (W/cm²)not applicable
In-situ Ispta (W/cm²)not applicable
Protocol, in the paper’s words

30 train bursts of 0.5 s every 20 s (10 min total); each burst is a 300 kHz monophasic pulse train with pulse duration half of the event period (150,000 pulses per burst). Drive amplitude +5 V or +10 V; no acoustic calibration was performed.

Flags from extraction

  • exposures[0].timing.pulse_duration_ms — Burst rule: the 0.5 s 'train burst' is the gated unit repeated every 20 s, so recorded as pulse duration; within it the carrier is a 300 kHz monophasic square wave with pulse duration half the event period.
  • exposures[0].timing.pulse_repetition_frequency_hz — Converted from the stated 20 s train burst period (1/20 s).
  • exposures[0].timing.duty_cycle_pct — Not stated; not computed.
  • exposures[0].free_field.pressure_kpa — Paper states direct acoustic pressure or intensity calibration was not performed; drive voltage only.
  • exposures[0].device.family — Transducer described only as custom immersion-type; maker not named, so classed as custom_built.
  • n_subjects — n = 3 refers to independent culture preparations; MTS used 5 biological replicates.