← Explore

Repeated application of transcranial ultrasound maintains spatial and recognition memory in 5xFAD mice with reduction of amyloid-β burden

Seung-Schik Yoo, Anvita Reddy, William Carroll, Kanyapat Ploypradith

PLOS One 2025 · 10.1371/journal.pone.0336114

rodentalzheimers diseasebehaviourhistology molecular

Abstract

Pharmacological removal of amyloid beta protofibrils has emerged as a promising therapeutic strategy to delay the onset of Alzheimer's disease (AD) symptoms. As a non-pharmacological and noninvasive alternative, transcranial application of low-intensity ultrasound through intact skull can induce convective acoustic streaming, which has been shown to enhance cerebrospinal fluid solute transport and facilitate the clearance of interstitial solutes. This has led to the development of device-based approaches aimed at removing the precursors of amyloid beta (Aβ) plaques and mitigating cognitive decline in AD. We applied non-thermal, non-cavitational ultrasound (400 kHz frequency) in a pulsed mode (75 ms pulse duration, 2 Hz repetition rate) to the hippocampal region of male 5xFAD mice for 30 minutes weekly, starting at 10 weeks of age and continuing for 15 weeks (until 6 months of age). Spatial and recognition memory performance was assessed monthly using the Y-maze spontaneous alternation (SA) and novel object recognition (NOR) tests. A control group of age-matched mice underwent the same procedures with receiving zero acoustic output. Mice subjected to transcranial ultrasound (tUS) treatment maintained both SA and NOR performance throughout the entire experimental period, whereas mice that received sham tUS exhibited a progressive decline in memory beginning at 3-4 months of age. Congo Red staining of the brain sections revealed a significant (> 40%) reduction in Aβ plaques in the sonicated group. Histological analysis confirmed that repeated ultrasound exposure did not cause any detectable tissue damage. These findings suggest that low intensity tUS may serve as a novel, noninvasive therapeutic strategy to delay the onset of AD symptoms through the reduction of Aβ burden.

Abstract via europepmc.

Speciesmouse (5xFAD, B6SJL)
Subjects6 animals
Sessions per subject15
Randomisedyes
Blindingsingle
Sham / controlinactive transducer
Auditory controlnot reported
Readout timingoffline
Anaesthesiaanaesthetised
Readoutsbehaviour, histology molecular — Y-maze spontaneous alternation; novel object recognition; Congo red amyloid plaque counts; H&E
Direction of effectnot assessedWeekly hippocampal tUS preserved spatial and recognition memory and reduced amyloid plaque density by more than 40% versus sham in 5xFAD mice.
Adverse eventsnone observedH&E and VAF staining showed no structural abnormalities, damage or ischemic injury; vital signs monitored during sonication.

Exposures

Exposure 1: Hippocampal tUS, 30 min weekly

Target: hippocampus — “the hippocampal region”
Device: Ultran · Ultran Group · WS100-0.5-P38 ✓

Pulse timing
Waveformpulsed
Fundamental frequency (kHz)400✓✓✓
Pulse duration (ms)75✓✓✓
Pulse repetition frequency (Hz)2✓✓✓
Duty cycle (%)15pulse duration × PRF gives 15%✓✓✓⚑
Sonication duration (s)1,800✓✓✓
Pressure and intensity, by domain
Free-field pressure (kPa)770✓✓✓⚑
Free-field Isppa (W/cm²)20✓✓✓⚑
Free-field Ispta (W/cm²)3✓✓✓
In-situ estimatenot reported
In-situ pressure (kPa)not reported
In-situ Isppa (W/cm²)not reported
In-situ Ispta (W/cm²)not reported
Protocol, in the paper’s words

Pulsed, 75 ms pulse duration, 2 Hz PRF, 30 minutes per session under isoflurane, weekly for 15 weeks from 11 weeks of age; sham group had zero acoustic output.

Flags from extraction

  • n_subjects — 12 mice total, 6 per group; only the 6 in the tUS+ group were sonicated.
  • blinding — Behavioural and histology raters were blinded to condition; sonication itself could not be blinded as far as stated.
  • exposures[0].free_field.pressure_kpa — 770 kPa is the maximum rarefactional pressure; field mapped in degassed water tank.
  • exposures[0].free_field.isppa_w_cm2 — Intensities stated without explicit domain; assigned to free field because the pressure field was calibrated in a degassed water tank.
  • exposures[0].timing.duty_cycle_pct — Duty cycle of 15% stated as 'Considering 15% duty cycle'; 75 ms x 2 Hz agrees.