← Explore

Mechanical artifacts during transcranial focused ultrasound mimic biologically evoked responses

Duc T Nguyen, Elisa E Konofagou, Jacek P Dmochowski

Brain Stimulation 2025 · 10.1016/j.brs.2025.05.114

rodenthealthyinvasive electrophysiology
Speciesrat
Subjectsnot reported animals
Sessions per subjectnot reported
Randomisednot reported
Blindingnot reported
Sham / controlinactive transducer, active control site
Auditory controlcontrol experiment
Readout timingonline
Anaesthesiaanaesthetised
Readoutsinvasive electrophysiology — 32-channel silicon microelectrode LFP and multi-unit activity; spatial PCA of LFP
Direction of effectmixed or uncleartFUS evoked a stereotyped LFP response time-locked to sonication onset and offset that was also present post mortem and absent with sham and olfactory bulb sonication; the authors conclude it is a mechanical electrode artifact rather than a neural effect.
Adverse eventsnot reported

Exposures

Exposure 1: tFUS to hippocampus (AM, CW, PW)

Target: hippocampus — “hippocampus”
Device: not reported

Pulse timing
Waveformother_patterned, continuous, pulsed
Fundamental frequency (kHz)2,500✓✓✓
Pulse duration (ms)not reported
Pulse repetition frequency (Hz)not reported
Duty cycle (%)not reported
Sonication duration (s)1✓✓✓
Pressure and intensity, by domain
Free-field pressure (kPa)not reported
Free-field Isppa (W/cm²)not reported
Free-field Ispta (W/cm²)not reported
In-situ estimatenot reported
In-situ pressure (kPa)not reported
In-situ Isppa (W/cm²)not reported
In-situ Ispta (W/cm²)not reported
Ispta, domain unspecified (W/cm²)0.013, 3.3swept✓✓✓⚑
Protocol, in the paper’s words

1 s sonications spaced 5-10 s apart at five intensities and three waveforms (amplitude modulated, continuous wave, pulsed wave) to the anaesthetised rat hippocampus; also repeated post mortem; sham was a 1 cm air gap and an active control sonicated the contralateral olfactory bulb. Pulsed-wave and AM parameters are not given.

Flags from extraction

  • exposures[0].unspecified_domain.ispta_w_cm2 — Range 13 mW/cm2 to 3.3 W/cm2 Ispta from text; Figure 1 legend gives the lowest of five intensities as 52 mW/cm2. Domain not stated.
  • n_subjects — Number of animals not stated; n = 300 trials per condition only.
  • exposures[0].timing — PRF, duty cycle and pulse duration of the pulsed-wave and AM conditions are not given.
  • direction_of_effect — Study is about a recording artifact; the evoked response is attributed to electrode motion.
  • exposures[0].device — Transducer maker not named; 2.5 MHz only.