Ultrasound Flow Imaging Study on Rat Brain with Ultrasound and Light Stimulations
Junhang Zhang, Chen Gong, Zihan Yang, Fan Wei, Xin Sun, Jie Ji, Yushun Zeng, Chi-feng Chang, Xunan Liu, Deepthi S. Rajendran Nair, Biju B. Thomas, Qifa Zhou
Bioengineering 2024 · 10.3390/bioengineering11020174
Abstract
Functional ultrasound (fUS) flow imaging provides a non-invasive method for the in vivo study of cerebral blood flow and neural activity. This study used functional flow imaging to investigate rat brain's response to ultrasound and colored-light stimuli. Male Long-Evan rats were exposed to direct full-field strobe flashes light and ultrasound stimulation to their retinas, while brain activity was measured using high-frequency ultrasound imaging. Our study found that light stimuli, particularly blue light, elicited strong responses in the visual cortex and lateral geniculate nucleus (LGN), as evidenced by changes in cerebral blood volume (CBV). In contrast, ultrasound stimulation elicited responses undetectable with fUS flow imaging, although these were observable when directly measuring the brain's electrical signals. These findings suggest that fUS flow imaging can effectively differentiate neural responses to visual stimuli, with potential applications in understanding visual processing and developing new diagnostic tools.
Abstract via europepmc.
Exposures
Exposure 1: Ultrasound stimulation of the rat eye/retina
Target: retina — “rats' eyeballs; retinas”
Device: custom-built
| Waveform | not reported | |
|---|---|---|
| Fundamental frequency (kHz) | 3,500 | ✓✓✓ |
| Pulse duration (ms) | 50 | ✓✓✓ |
| Pulse repetition frequency (Hz) | 1 | ✓✓✓ |
| Duty cycle (%) | not reportedpulse duration × PRF gives 5% | |
| Sonication duration (s) | not reported |
| Free-field pressure (kPa) | not reported | ⚑ |
|---|---|---|
| Free-field Isppa (W/cm²) | not reported | |
| Free-field Ispta (W/cm²) | not reported | |
| In-situ estimate | not reported | |
| In-situ pressure (kPa) | not reported | |
| In-situ Isppa (W/cm²) | not reported | |
| In-situ Ispta (W/cm²) | not reported |
Stimulation at two output voltages, 30 Vpp and 90 Vpp, for a 50 ms duration with a 1 s interval; fUS imaging used 90 Vpp with the same parameters. A hydrophone test used a 3.5 MHz sine wave in burst mode with 20 cycles.
Flags from extraction
n_subjects— Five rats stated for the comparative light/ultrasound imaging experiment; number for the EEG experiment not stated (10 trials).exposures[0].timing.waveform— Unclear whether the 50 ms stimulus is a single burst or a train; the 20-cycle burst is mentioned only for hydrophone characterisation.exposures[0].device.family— Author contributions say a co-author fabricated the stimulation transducer; no maker named.exposures[0].free_field.pressure_kpa— Only output voltages (30 and 90 Vpp) given; a hydrophone profile is in Fig. 1c but no pressure value is in the text.