Low-Intensity Focused Ultrasound Stimulation on Fingertip Can Evoke Fine Tactile Sensations and Different Local Hemodynamic Responses
Liuni Qin, Mingyang Dou, Lili Niu, Laixin Huang, Fei Li, Shichun Bao, Xinping Deng, Guanglin Li, Yanjuan Geng
IEEE Transactions on Neural Systems and Rehabilitation Engineering 2024 · 10.1109/tnsre.2024.3493925
Abstract
Low-intensity focused ultrasound stimulation (LIFUS) has been proved effective in eliciting vibrotactile in addition to warm, cold and nociceptive pain when applied to human peripheral endings. However, if it can evoke fine tactile sensations has been rarely investigated by far despite the importance of fine tactile feedback in motor control. To explore this issue, 14 healthy volunteers were recruited in this study. A psychophysical experiment was firstly conducted to determine the appropriate range of pulse repetition frequency (PRF) and acoustic intensity (AI). Then, participants were asked to perceive and discriminate different tactile stimulations under LIFUS, so as to evaluate if multiple fine tactile sensations could be reliably elicited by modulating the PRF and AI. For objective assessment, the local blood perfusion volume (BPV) response beneath stimulated fingertip was recorded and characterized. Our results showed that four types of tactile sensations, including tapping, vibrating, electrical, and pressure could be reliably elicited by modulating the PRF and AI within a specific range, and there was a significant impact of PRF and AI on both participants' tactile discrimination and amplitude features of BPV response. This study would facilitate the application of LIFUS to some human-machine interaction scenarios, and shed valuable insights on the physiological mechanisms of peripherally applied ultrasound stimulation.
Abstract via europepmc.
Exposures
Exposure 1: Fingertip LIFUS, 250 kHz transducer
Target: other — “fingertip (right index finger)”
Device: other named manufacturer · Pantsd Inc., China · HN81C-750-250KC ✓
| Waveform | pulsed | |
|---|---|---|
| Fundamental frequency (kHz) | 250 | ✓✓✓ |
| Pulse duration (ms) | not reported | |
| Pulse repetition frequency (Hz) | 4, 88swept | ✓✓✓⚑ |
| Duty cycle (%) | 3 | ✓✓✓ |
| Sonication duration (s) | 1, 2swept | ✓✓✓ |
| Free-field pressure (kPa) | not reported | |
|---|---|---|
| Free-field Isppa (W/cm²) | 10.28, 28.02swept | ✓✓✓ |
| Free-field Ispta (W/cm²) | 0.22, 0.84swept | ✓✓✓ |
| In-situ estimate | not reported | |
| In-situ pressure (kPa) | not reported | |
| In-situ Isppa (W/cm²) | not reported | |
| In-situ Ispta (W/cm²) | not reported |
Pulsed ultrasound at 3% duty cycle with PRF selected per sensation (tapping 4-7 Hz, vibrating 14-24 Hz, electrical 63-72 Hz, pressure 80-88 Hz), 1 s or 2 s per stimulus (2 s in experiments 2 and 3), followed by 5 s rest in experiment 2 and 1 min inter-trial interval in experiment 3.
Exposure 2: Fingertip LIFUS, 500 kHz transducer
Target: other — “fingertip (right index finger)”
Device: other named manufacturer · NDT Inc., USA · IBP0.512 ✓
| Waveform | pulsed | |
|---|---|---|
| Fundamental frequency (kHz) | 500 | ✓✓✓ |
| Pulse duration (ms) | not reported | |
| Pulse repetition frequency (Hz) | 4, 88swept | ✓✓✓ |
| Duty cycle (%) | 3 | ✓✓✓ |
| Sonication duration (s) | 1, 2swept | ✓✓✓ |
| Free-field pressure (kPa) | 1,790 | ✓✓✓ |
|---|---|---|
| Free-field Isppa (W/cm²) | 10.28, 35.33swept | ✓✓✓ |
| Free-field Ispta (W/cm²) | 0.31, 1.15swept | ✓✓✓ |
| In-situ estimate | not reported | |
| In-situ pressure (kPa) | not reported | |
| In-situ Isppa (W/cm²) | not reported | |
| In-situ Ispta (W/cm²) | not reported |
Pulsed ultrasound at 3% duty cycle with PRF selected per sensation (tapping 4-7 Hz, vibrating 14-24 Hz, electrical 63-72 Hz, pressure 80-88 Hz), 1 s or 2 s per stimulus (2 s in experiments 2 and 3), followed by 5 s rest in experiment 2 and 1 min inter-trial interval in experiment 3.
Flags from extraction
n_subjects— 14 recruited; 8 took part in experiment 1 and 12 in experiments 2 and 3exposures[0].unspecified_domain.isppa_w_cm2— Range across Table I (experiment 2) rows for this transducer; experiment 1 used up to 56.7 W/cm2 for 500 kHz; AI-voltage relation was calibrated in a water bath but intensity domain is not stated explicitlyexposures[0].timing.pulse_repetition_frequency_hz— PRF range from Table I across four sensation types; experiment 1 swept 2-90 Hzexposures[0].target— Peripheral fingertip stimulation; no target term fits, recorded as othersham_type— 'No stimulation' trials were interleaved, otherwise no shamexposures[1].unspecified_domain.pressure_kpa— Highest peak pressure of 1.79 MPa given for the whole study without frequency; not entered