Bidirectional Neuronal Control of Epileptiform Activity by Repetitive Transcranial Focused Ultrasound Stimulations

Taewon Choi, Minseok Koo, Jaesoon Joo, Taekyung Kim, Young‐Min Shon, Jinhyoung Park

Advanced Science 2024 · 10.1002/advs.202302404

rodentepilepsyeeg megcerebral haemodynamicshistology molecularother

Abstract

Repetitive stimulation procedures are used in neuromodulation techniques to induce persistent excitatory or inhibitory brain activity. The directivity of modulation is empirically regulated by modifying the stimulation length, interval, and strength. However, bidirectional neuronal modulations using ultrasound stimulations are rarely reported. This study presents bidirectional control of epileptiform activities with repetitive transcranial-focused ultrasound stimulations in a rat model of drug-induced acute epilepsy. It is found that repeated transmission of elongated (40 s), ultra-low pressure (0.25 MPa) ultrasound can fully suppress epileptic activities in electro-encephalography and cerebral blood volume measurements, while the change in bursting intervals from 40 to 20 s worsens epileptic activities even with the same burst length. Furthermore, the suppression induced by 40 s long bursts is transformed to excitatory states by a subsequent transmission. Bidirectional modulation of epileptic seizures with repeated ultrasound stimulation is achieved by regulating the changes in glutamate and γ-Aminobutyric acid levels, as confirmed by measurements of expressed c-Fos and GAD65 and multitemporal analysis of neurotransmitters in the interstitial fluid obtained via microdialysis.

Abstract via europepmc.

Speciesrat (Sprague-Dawley)
Subjects5, 5, 5, 5, 5, 5, 6, 6, 6, 6, 6, 5, 5, 5, 3swept animals
Sessions per subjectnot reported
Randomisednot reported
Blindingnot reported
Sham / controlno treatment control
Auditory controlnot reported
Readout timingboth
Anaesthesiaanaesthetised
Readoutseeg meg, cerebral haemodynamics, histology molecular, other — Epileptic spike counts and EEG spectral power; 530 nm reflectance CBV; c-Fos, GAD65, Iba1, GFAP immunohistochemistry; microdialysis GABA and glutamate by LC-MS/MS
Direction of effectbidirectionalRepeated 40 s bursts at 0.25 MPa with 40 s intervals suppressed PTZ-induced epileptiform activity; shortening the interval to 20 s, or following with the 1 MPa 0.25 s sequence (hybrid), worsened it.
Adverse eventsnone observedNissl staining after TXH_0.25_30 and TXL_40_40 showed no damage to the rat brain.

Exposures

Exposure 1: rtFUS to right anterior thalamic nucleus (TXH_0.25_30, TXL_40_40, TXL_10_50, TXL_20_40, TXL_40_20, TX_HYBRID)

Target: anterior thalamic nucleus — “right anterior thalamic nucleus (ATN)”
Device: custom-built · Del Piezo Specialties LLC (PZT element supplier) · 690 kHz single-element ring transducer (PZT DL-47), 10/31 mm inner/outer diameter ✓

Pulse timing
Waveformpulsed
Fundamental frequency (kHz)690✓✓✓
Pulse duration (ms)5✓✓✓⚑
Pulse repetition frequency (Hz)100✓✓✓
Duty cycle (%)50pulse duration × PRF gives 50%✓✓✓
Sonication duration (s)0.25, 10, 20, 40swept✓✓✓⚑
Pressure and intensity, by domain
Free-field pressure (kPa)not reported
Free-field Isppa (W/cm²)not reported
Free-field Ispta (W/cm²)not reported
In-situ estimatenot reported
In-situ pressure (kPa)not reported
In-situ Isppa (W/cm²)not reported
In-situ Ispta (W/cm²)not reported
Pressure, domain unspecified (kPa)250, 1,000swept✓✓✓⚑
Protocol, in the paper’s words

Two families of repeated sonication: TXL, six repetitions of a 0.25 MPa burst of 10, 20 or 40 s with 50, 40, 40 or 20 s intervals; and TXH, eleven repetitions of a 1 MPa, 0.25 s burst with 30 s intervals (50% duty cycle, 100 Hz PRF, 5 ms bursts of 3450 cycles). TX_HYBRID is TXL_40_40 then TXH_0.25_30 after a 3 min rest.

Flags from extraction

  • n_subjects — Fifty-nine rats stated for the experiments; microdialysis used twenty additional rats per the Methods, so overlap is unclear.
  • exposures[0].unspecified_domain.pressure_kpa — 0.25 MPa and 1 MPa given without stating water or in-brain.
  • exposures[0].timing.waveform — TXH is stated as 50% duty at 100 Hz PRF (pulsed); TXL is called a 'consecutive burst train' with no internal gating stated.
  • exposures[0].timing.pulse_duration_ms — 5 ms, duty cycle 50% and PRF 100 Hz are stated for the TXH sequence only; not applicable as stated to TXL.
  • exposures[0].timing.sonication_duration_s — List of burst lengths across sequences: 0.25 s (TXH), 10, 20, 40 s (TXL).
  • exposures[0].device.family — Transducer is described as fabricated, with a PZT element from Del Piezo Specialties; recorded as custom_built.