Remus: System for Remote Deep Brain Interventions

Taylor D. Webb, Matthew G. Wilson, Henrik Odéen, Jan Kubanek

2021 · 10.1101/2021.05.05.442844

nonhuman primatehealthybehaviour

Abstract

Motivation Transcranial focused ultrasound brings personalized medicine to the human brain. Ultrasound can modulate neural activity or release drugs in specific neural circuits but this personalized approach requires a system that delivers ultrasound into specified targets flexibly and on command. Summary We developed a remote ultrasound system (Remus) that programmatically targets deep brain regions with high spatiotemporal precision and in a multi-focal manner. We validated these functions by safely modulating two deep brain nuclei—the left and right lateral geniculate nucleus–in a task-performing non-human primate. This flexible system will enable researchers and clinicians to diagnose and treat specific deep brain circuits in a noninvasive yet targeted manner, thus embodying the promise of personalized treatments of brain disorders. Animated graphical abstract: onetarget.us/download/rem .

Abstract via europepmc.

Speciesrhesus macaque (Macaca mulatta)
Subjects1 animals
Sessions per subject39
Randomisedyes
Blindingnot reported
Sham / controlno treatment control
Auditory controlother
Readout timingonline
Anaesthesiaawake
Readoutsbehaviour — visual choice task (left/right saccade choice), eye tracking
Direction of effectbidirectionalPulsed stimuli at 10% duty cycle produced an ipsilateral choice bias, read as inhibition; continuous stimuli produced a contralateral bias, read as excitation.
Adverse eventsnone observedThe subject showed no signs of discomfort; discrimination accuracy increased over 39 sessions, taken as behavioural evidence of no harm.

Exposures

Exposure 1: Left and right LGN, 650 kHz, 10%, 50% and 100% duty

Target: lateral geniculate nucleus — “left and right lateral geniculate nucleus”
Device: other named manufacturer · Doppler Electronic Technologies, Guangzhou, China · custom 256 element transducer ✓

Pulse timing
Waveformcontinuous, pulsed
Fundamental frequency (kHz)650✓✓✓
Pulse duration (ms)not reported⚑
Pulse repetition frequency (Hz)500✓✓✓
Duty cycle (%)10, 50, 100swept✓✓✓⚑
Sonication duration (s)0.3✓✓✓
Pressure and intensity, by domain
Free-field pressure (kPa)2,400✓✓✓⚑
Free-field Isppa (W/cm²)not reported
Free-field Ispta (W/cm²)not reported
In-situ estimatemeasurementsingle value
In-situ pressure (kPa)650, 770swept✓✓✓⚑
In-situ Isppa (W/cm²)not reported
In-situ Ispta (W/cm²)not reported
Protocol, in the paper’s words

A 300 ms stimulus was delivered 150 ms before fixation point offset, into the left or right LGN every 6-14 s, side randomised, interspersed with no-ultrasound trials. Stimuli were either continuous (100% duty) or pulsed at 10% duty with a 500 Hz PRF; a 50% duty condition is mentioned in the supplement without PRF.

Flags from extraction

  • exposures[0].in_situ.pressure_kpa — Pressure at target was estimated from MR thermometry (heating of the focus), recorded here as method measurement. The figure legend gives 750 kPa; the Methods give 770 kPa (right LGN) and 650 kPa (left LGN).
  • exposures[0].free_field.pressure_kpa — Hydrophone free-field pressure at the same input voltage; the paper does not state whether the waveform was pulsed or continuous for this measurement.
  • exposures[0].timing.duty_cycle_pct — 50% duty appears only in the supplementary figure legend; PRF and pulse duration are stated only for the 10% condition.
  • exposures[0].timing.pulse_duration_ms — Not stated; the paper gives only duty cycle and PRF.
  • auditory_control — No auditory control was run; the authors argue from the left/right and waveform specificity of the effect that an auditory artefact is unlikely.
  • sham_type — Trials without ultrasound were randomly interspersed within sessions; there was no separate sham arm.
  • exposures[0].device.family — Custom transducer credited to Doppler Electronic Technologies; driven by a Verasonics system (named in the Software section).