Epidermal Electrode Technology for Detecting Ultrasonic Perturbation of Sensory Brain Activity

Stanley Huang, Jonathan A. N. Fisher, Meijun Ye, Yun-Soung Kim, Rui Ma, Marjan Nabili, Victor Krauthamer, Matthew R. Myers, Todd P. Coleman, Cristin G. Welle

IEEE Transactions on Biomedical Engineering 2018 · 10.1109/tbme.2017.2713647

rodenthealthyeeg meg

Abstract

Objective We aim to demonstrate the in vivo capability of a wearable sensor technology to detect localized perturbations of sensory-evoked brain activity. Methods Cortical somatosensory evoked potentials (SSEPs) were recorded in mice via wearable, flexible epidermal electrode arrays. We then utilized the sensors to explore the effects of transcranial focused ultrasound, which noninvasively induced neural perturbation. SSEPs recorded with flexible epidermal sensors were quantified and benchmarked against those recorded with invasive epidural electrodes. Results We found that cortical SSEPs recorded by flexible epidermal sensors were stimulus frequency dependent. Immediately following controlled, focal ultrasound perturbation, the sensors detected significant SSEP modulation, which consisted of dynamic amplitude decreases and altered stimulus-frequency dependence. These modifications were also dependent on the ultrasound perturbation dosage. The effects were consistent with those recorded with invasive electrodes, albeit with roughly one order of magnitude lower signal-to-noise ratio. Conclusion We found that flexible epidermal sensors reported multiple SSEP parameters that were sensitive to focused ultrasound. This work therefore 1) establishes that epidermal electrodes are appropriate for monitoring the integrity of major CNS functionalities through SSEP; and 2) leveraged this technology to explore ultrasound-induced neuromodulation. The sensor technology is well suited for this application because the sensor electrical properties are uninfluenced by direct exposure to ultrasound irradiation. Significance The sensors and experimental paradigm we present involve standard, safe clinical neurological assessment methods and are thus applicable to a wide range of future translational studies in humans with any manner of health condition.

Abstract via europepmc.

Speciesmouse (C57/B6)
Subjects14 animals
Sessions per subjectnot reported
Randomisednot reported
Blindingnot reported
Sham / controlinactive transducer
Auditory controlnot reported
Readout timingoffline
Anaesthesiaanaesthetised
Readoutseeg meg — Somatosensory evoked potentials (median nerve stimulation) recorded with flexible epidermal electrodes and epidural electrodes
Direction of effectinhibitorySSEP peak-to-peak amplitude dropped immediately after sonication, proportionally to dose (40% at 1.2 J, 68% at 3 J, 77% at 9 J), with incomplete recovery at higher doses; sham had no effect.
Adverse eventsnot reportedAuthors state the RMS pressure per pulse is approximately one half the value reported to elicit histological evidence of mild brain trauma.

Exposures

Exposure 1: Focused ultrasound perturbation of frontal lobe (40, 100 or 300 pulses)

Target: frontal lobe — “the frontal lobe”
Device: Sonic Concepts · Sonic Concepts · H102 ✓

Pulse timing
Waveformpulsed
Fundamental frequency (kHz)1,100✓✓✓
Pulse duration (ms)10✓✓✓
Pulse repetition frequency (Hz)not reported⚑
Duty cycle (%)not reported
Sonication duration (s)not reported⚑
Pressure and intensity, by domain
Free-field pressure (kPa)not reported
Free-field Isppa (W/cm²)not reported
Free-field Ispta (W/cm²)not reported
In-situ estimatesimulationsingle value
In-situ pressure (kPa)not reported⚑
In-situ Isppa (W/cm²)85✓✓✓⚑
In-situ Ispta (W/cm²)not reported
Pressure, domain unspecified (kPa)4,000✓✓✓⚑
Protocol, in the paper’s words

Pulse train of 1.1 MHz sinusoidal pulses, each of duration 10 ms, followed by an off time of 200 ms; 40, 100 or 300 pulses per animal.

Flags from extraction

  • exposures[0].timing.pulse_repetition_frequency_hz — PRF and duty cycle not stated; only 10 ms pulses with a 200 ms off time.
  • exposures[0].timing.sonication_duration_s — Only pulse counts (40/100/300) given; no total duration.
  • exposures[0].unspecified_domain.pressure_kpa — 19 MPa peak positive pressure at the focus (converted to kPa); domain (water vs head) not clearly stated.
  • exposures[0].in_situ.isppa_w_cm2 — Intensity of about 85 W/cm2 computed from simulated RMS pressure 1.6 MPa by plane-wave relation, just inside the skull; paper does not label it as pulse-average, and the figure does not obviously match 1.6 MPa RMS.