Effects of Pulsed Ultrasound Therapy on Sensory Nerve Conduction Parameters and the Pain Threshold Perceptions in Humans

Othmar Schuhfried, Damir Vukanovic, Christian Kollmann, Karin Pieber, Tatjana Paternostro‐Sluga

PM&R 2017 · 10.1016/j.pmrj.2016.11.009

human healthyhealthyemg mepbehaviour

Abstract

Background Therapeutic ultrasound is an often-used clinical modality in the nonsurgical treatment of entrapment neuropathies. To date, the possible mechanism of action of pulsed ultrasound therapy on the peripheral nerve in the treatment of entrapment neuropathies is unclear. Objective To examine the effects of pulsed ultrasound therapy on peripheral nerve conduction parameters. Design A prospective, randomized, single blind, crossover study. Setting Outpatient clinic of a university department of physical medicine and rehabilitation. Participants Twelve healthy volunteers between 22 and 38 years of age (8 male, 4 female). Methods Each patient (blinded) received ultrasound therapy (1W/cm 2 , pulsed: 1:5; over the course of the superficial branch of the radial nerve of the nondominant arm) and placebo (intensity: zero). The interval between the individual interventions was 1 week. Main outcome measurement The sensory nerve conduction velocity, sensory nerve action potential, supramaximal stimulation intensity of the sensory fibers of the radial nerve, and the pressure pain threshold in the sensory area of the radial nerve before and after an ultrasound-therapy and placebo intervention. To compare the results of the intervention with placebo, a paired-samples t test was applied. Results Compared with placebo, a significant increase after pulsed ultrasound therapy was found for the supramaximal stimulation intensity (P = .02). For the other primary outcome parameters, a significant difference was not found. Conclusions The immediate effect of pulsed ultrasound therapy on a sensory nerve is minimal. Therefore, the previously reported benefit of pulsed ultrasound therapy in entrapment neuropathies might be not due to its effect on the sensory nerve. Level of evidence I.

Abstract via europepmc.

Specieshuman
Subjects12 participants
Sessions per subject1
Randomisedyes
Blindingsingle
Sham / controlinactive transducer
Auditory controlnot reported
Readout timingoffline
Anaesthesianot applicable
Readoutsemg mep, behavioursensory antidromic nerve conduction velocity (sNCV) and sensory nerve action potential (sNAP) of the radial nerve; supramaximal stimulation intensity (SSI); pressure pain threshold (PPT) by dolorimeter; skin temperature by infrared thermography
Direction of effectmixed or unclearPulsed ultrasound significantly increased the supramaximal stimulation intensity (SSI) needed versus placebo, but sensory nerve conduction velocity, sensory nerve action potential amplitude and pressure pain threshold did not differ from placebo.
Adverse eventsnot reported

Exposures

Exposure 1: Pulsed ultrasound to the superficial branch of the radial nerve

Target: radial nerve — “superficial branch of the radial nerve of the nondominant arm
Device: other named manufacturer · GBO Medizintechnik, Rimbach, Germany · Sonostat 133

Pulse timing
Waveformpulsed
Fundamental frequency (kHz)3,000✓✓
Pulse duration (ms)not reported
Pulse repetition frequency (Hz)not reported
Duty cycle (%)not reported
Sonication duration (s)300✓✓
Pressure and intensity, by domain
Free-field pressure (kPa)not reported
Free-field Isppa (W/cm²)not reported
Free-field Ispta (W/cm²)not reported
In-situ estimatenot reported
In-situ pressure (kPa)not reported
In-situ Isppa (W/cm²)not reported
In-situ Ispta (W/cm²)not reported
Isppa, domain unspecified (W/cm²)1✓✓
Protocol, in the paper’s words

Therapeutic ultrasound was applied with an intensity of 1 W/cm2, pulsed 1:5, frequency 3 MHz, via a transducer with a surface area of 2.5 cm2, at the radial side of the forearm from 5 to 15 cm proximal to the metacarpophalangeal joint of the thumb, over the course of the superficial branch of the radial nerve, for 5 minutes, with the transducer moved dynamically over the treatment area. Placebo used the same device, area and duration with intensity set to zero.

Flags from extraction

  • exposures[0].timing.duty_cycle_pctPaper states the pulse ratio as 'pulsed 1:5' without defining whether this is on:off or on:total; left duty_cycle_pct not_reported rather than assume a convention.
  • exposures[0].unspecified_domain.ispta_w_cm2Paper reports only 'intensity 1 W/cm2' without specifying ISATA/ISPTA/domain; placed in unspecified_domain.
  • n_sessions_per_subjectCrossover design gave each subject one real-ultrasound session and one placebo session on separate days; n_sessions_per_subject counts only the real-ultrasound session.