← Explore

Effect of noninvasive focused ultrasound stimulation on gamma oscillations in rat hippocampus

Yi Yuan, Jiaqing Yan, Zhitao Ma, Xiaoli Li

NeuroReport 2016 · 10.1097/wnr.0000000000000572

rodenthealthyinvasive electrophysiology

Abstract

In recent years, noninvasive focused ultrasound stimulation (FUS), with the advantage of high spatial resolution and high penetration depth, has developed rapidly for modulating neuron activities in the brain. Gamma oscillations serve to synchronize neurons and play important roles in cortical information processing and cognitive function. However, how FUS modulates gamma oscillations in the rat hippocampus is not well understood. In this work, we characterized the interactions between the gamma amplitude and phases of the delta, theta, and alpha bands during FUS. Our results show that FUS can significantly modulate the extent of phase-locked gamma amplitude and phase-amplitude coupling of brain oscillations. In summary, FUS can modulate gamma oscillations in the rat hippocampus, indicating its potential as a powerful noninvasive method to interfere with brain rhythms for diagnostic and therapeutic purposes.

Abstract via europepmc.

Speciesrat (Sprague-Dawley)
Subjects5 animals
Sessions per subjectnot reported
Randomisednot reported
Blindingnot reported
Sham / controlnone
Auditory controlcontrol experiment
Readout timingonline
Anaesthesiaanaesthetised
Readoutsinvasive electrophysiology — hippocampal LFP, phase-amplitude coupling of gamma
Direction of effectmixed or unclearDuring FUS, gamma amplitude locked to delta, theta and alpha phases and phase-amplitude coupling were greater than in the pre-FUS control.
Adverse eventsnot reported

Exposures

Exposure 1: 2.5 MHz FUS to hippocampal CA1

Target: CA1 — “CA1 of the rat hippocampus”
Device: not reported · focused transducer driven by USB-UT350T transmitter card (US Ultratek)

Pulse timing
Waveformpulsed
Fundamental frequency (kHz)2,500✓✓✓
Pulse duration (ms)0.0016✓✓✓⚑
Pulse repetition frequency (Hz)500✓✓✓
Duty cycle (%)not reportedpulse duration × PRF gives 0.08%⚑
Sonication duration (s)0.16✓✓✓
Pressure and intensity, by domain
Free-field pressure (kPa)not reported
Free-field Isppa (W/cm²)not reported
Free-field Ispta (W/cm²)not reported
In-situ estimatenot reported
In-situ pressure (kPa)not reported
In-situ Isppa (W/cm²)not reported
In-situ Ispta (W/cm²)not reported
Isppa, domain unspecified (W/cm²)9.8✓✓✓⚑
Ispta, domain unspecified (W/cm²)0.00784✓✓✓⚑
Protocol, in the paper’s words

Pulses of four cycles at 500 Hz pulse repetition rate, each stimulus consisting of 80 ultrasound pulses; stimulation duration 160 ms and pulse duration 1.6 microseconds.

Flags from extraction

  • exposures[0].unspecified_domain.isppa_w_cm2 — Intensity measured with an ultrasonic power measuring instrument; medium and whether skull in path not stated.
  • exposures[0].unspecified_domain.ispta_w_cm2 — Paper gives 7.84 mW/cm2; converted to W/cm2 as 0.00784 (unit conversion only).
  • exposures[0].timing.pulse_duration_ms — Paper states 1.6 microseconds; recorded as 0.0016 ms.
  • exposures[0].timing.duty_cycle_pct — Not stated; not computed.
  • auditory_control — Authors compared LFP before and during ultrasound emission with the transducer moved relative to the brain, concluding transducer sound had no effect; treated as a control experiment.
  • sham_type — Pre-FUS recording served as the control; no sham arm.
  • direction_of_effect — Outcome is changes in gamma coupling, not clearly excitatory or inhibitory.