Noninvasive Focused Ultrasound Stimulation Can Modulate Phase-Amplitude Coupling between Neuronal Oscillations in the Rat Hippocampus
Yi Yuan, Jiaqing Yan, Zhitao Ma, Xiaoli Li
Frontiers in Neuroscience 2016 · 10.3389/fnins.2016.00348
Abstract
Noninvasive focused ultrasound stimulation (FUS) can be used to modulate neural activity with high spatial resolution. Phase-amplitude coupling (PAC) between neuronal oscillations is tightly associated with cognitive processes, including learning, attention, and memory. In this study, we investigated the effect of FUS on PAC between neuronal oscillations and established the relationship between the PAC index and ultrasonic intensity. The rat hippocampus was stimulated using focused ultrasound at different spatial-average pulse-average ultrasonic intensities (3.9, 9.6, and 19.2 W/cm(2)). The local field potentials (LFPs) in the rat hippocampus were recorded before and after FUS. Then, we analyzed PAC between neuronal oscillations using a PAC calculation algorithm. Our results showed that FUS significantly modulated PAC between the theta (4-8 Hz) and gamma (30-80 Hz) bands and between the alpha (9-13 Hz) and ripple (81-200 Hz) bands in the rat hippocampus, and PAC increased with incremental increases in ultrasonic intensity.
Abstract via europepmc.
Exposures
Exposure 1: FUS to rat hippocampus at 3.9, 9.6, 19.2 W/cm2
Target: hippocampus — “rat hippocampus”
Device: not reported
| Waveform | pulsed | |
|---|---|---|
| Fundamental frequency (kHz) | 2,500 | ✓✓✓ |
| Pulse duration (ms) | 0.0016 | ✓✓✓⚑ |
| Pulse repetition frequency (Hz) | 500 | ✓✓✓ |
| Duty cycle (%) | not reportedpulse duration × PRF gives 0.08% | |
| Sonication duration (s) | 0.16 | ✓✓✓⚑ |
| Free-field pressure (kPa) | not reported | |
|---|---|---|
| Free-field Isppa (W/cm²) | not reported | |
| Free-field Ispta (W/cm²) | not reported | |
| In-situ estimate | not reported | |
| In-situ pressure (kPa) | not reported | |
| In-situ Isppa (W/cm²) | not reported | |
| In-situ Ispta (W/cm²) | not reported | |
| Isppa, domain unspecified (W/cm²) | 3.9, 9.6, 19.2swept | ✓✓✓⚑ |
A single stimulation consisted of 4-cycle (1.6 us) ultrasound pulses at a PRF of 500 Hz and a duration of 160 ms (80 repetitions). Transducer coupled via a plastic cone and gel; LFPs recorded before and after FUS.
Flags from extraction
exposures[0].unspecified_domain.isppa_w_cm2— Paper calls these 'spatial-average pulse-average' intensities measured with a sound power meter of 9.5 mm diameter; the metric is not Isppa and the medium is not stated.exposures[0].timing.pulse_duration_ms— Stated as 4 cycles (1.6 us); converted to ms.exposures[0].timing.sonication_duration_s— Duration of 160 ms (80 repetitions) converted to s; inter-stimulus interval and number of stimulations not stated.exposures[0].device.family— Transducer maker not named; only the Ultratek driver card.