Reversible Block of Nerve Conduction by Ultrasound

ROBERT R. YOUNG

Archives of Neurology 1961 · 10.1001/archneur.1961.00450070085009

ex vivo tissuehealthyinvasive electrophysiology
Speciesfrog
Subjects15 preparations
Sessions per subjectnot applicable
Randomisednot applicable
Blindingnot applicable
Sham / controlnone
Auditory controlnot reported
Readout timingboth
Anaesthesianot applicable
Readoutsinvasive electrophysiologyCompound action potentials of alpha, beta and gamma fibre groups recorded from the sciatic nerve
Direction of effectinhibitoryFocused ultrasound reversibly or irreversibly blocked conduction in the sciatic nerve; smaller myelinated fibres (gamma, then beta) were blocked before larger alpha fibres, and repeated ultrasound produced cumulative, increasing depression of conduction.
Adverse eventsnot applicable

Exposures

Exposure 1: Focused ultrasound irradiation of frog sciatic nerve

Target: sciatic nerve — “sciatic nerve
Device: custom-built

Pulse timing
Waveformpulsed
Fundamental frequency (kHz)2,700✓✓
Pulse duration (ms)140, 1,200swept✓✓
Pulse repetition frequency (Hz)not reported
Duty cycle (%)not reported
Sonication duration (s)not reported
Pressure and intensity, by domain
Free-field pressure (kPa)not reported
Free-field Isppa (W/cm²)not reported
Free-field Ispta (W/cm²)not reported
In-situ estimatenot applicable
In-situ pressure (kPa)not applicable
In-situ Isppa (W/cm²)not applicable
In-situ Ispta (W/cm²)not applicable
Isppa, domain unspecified (W/cm²)1,150✓✓
Protocol, in the paper’s words

The ultrasound (2.7 megacycles per sec.) was administered in pulses of 0.14-1.2 sec. duration, with a 2-3 sec. interval between pulses. In each experiment the flux of ultrasound (pulse width and train length) was increased gradually until a level was reached which would affect conduction of impulses; depending on the effect desired, a pulse width of 0.5-0.8 sec. and a train length of 1-20 pulses were usually employed.

Flags from extraction

  • exposures[0].free_field.isppa_w_cm2Paper states only an undifferentiated 'intensity' (1,150 W/cm^2) calibrated at the focal region in saline; it does not specify spatial-peak pulse-average vs. temporal-average, and the nerve itself was covered in liquid petrolatum rather than saline during exposure, so the domain of this calibration value is uncertain.
  • exposures[0].timing.pulse_repetition_frequency_hzOnly an inter-pulse interval (2-3 s) and train lengths (1-20 pulses) are given; no explicit repetition rate or duty cycle is stated.